GAS SIDE WALL POWER VENTERS
Problem:
Tryin' to add a wood burning appliance to offset heating costs. Have 1
chimney with 1 flue that is used to vent an oil or gas furnace or boiler and the
one flue cannot be used for the 2 different burning appliances....
Solution: Side venting!!!
The wood or coal burner can use the existing flue, and the heating system can
now safely and economically vent out a side wall.
Call or e-mail us any time. We
will be happy to offer options, price and explain installation.
|
|
|
|
|
Side Wall Vent Systems save time and
money and are excellent for electric to gas/oil, renovations, new construction
or for replacing deteriorated chimneys.
Side wall venting saves costly materials
and labor on two, three or more story runs. It also increases living space by
cutting out interior chases. Proven safety interlocks assure proper exhaust, a
feature conventional chimneys do not offer in today's homes and buildings.
|
|
|
|
Safety and performance features
time-proven in over one million installations:
All operating components
located indoors for weather protection and easy servicing. |
Capacities up to 250,000
BTU/hr. |
Accommodates vent pipe runs up
to 100 equivalent feet. |
Regulated, consistent draft
throughout burner cycle. |
Built-in Fan Proving Switch
interlocks with gas valve. |
Standard 45 Second Post-Purge
Relay/Timer. |
Kit includes everything needed
for installation, except vent pipe. (HS-Series does not come with the
vent hood or Draft Control) |
AGA design certified for gas
furnaces, boilers, pool heaters, unit heaters and commercial water
heaters. (HS-Series is UL approved) |
HS Series
Models: HSJ, HS1, HS2
Used for Side wall venting
residential/light commercial natural gas, LP or oil fired equipment including:
Furnaces, boilers, water heaters and unit heaters. All models feature the new
UC1 Universal Control and a diaphragm Fan Proving Switch safety interlock which
will shut down the heating equipment if a venting malfunction occurs. Built-in
adjustable damper also allows regulation for maximum combustion efficiency. UC1
Universal Control features include; adjustable pre and post-purge settings, LED
Status/diagnostic indicators, Fan Prover switch monitoring. Interlocks with any
24-120 VAC burner control circuit and also includes "dry" contact actuation
option. Easily interlock multiple appliances with our MAC-Series multiple
appliance controls.
HSUL Series
Models: HSUL-J, HSUL-1,
HSUL-2
Designed for atmospheric 24V controlled gas
equipment. Includes a 24/115V switching relay and a factory set diaphragm Fan
Proving Switch. Built-in adjustable damper also allows
regulation for maximum combustion efficiency.
HS-Series
Residential/Light Commercial
MODEL
NUMBER |
VENT
PIPE
DIA. |
BTU/HR
INPUT |
MAX. PIPE
LENGTH (FEET)
AT STACK TEMP.
GAS FIRED
300 F
|
MAX. PIPE
LENGTH (FEET)
AT STACK TEMP.
GAS FIRED
400 F
|
MAX. PIPE
LENGTH (FEET)
AT STACK TEMP.
OIL FIRED
500 F
|
CFM AT 70 degrees
F.
(Static Pressure)
0" .50" .75"
1.0" 1.4"
|
**HSJ
**HSUL-J
|
4" |
50,000
75,000
100,000
125,000 |
100'
100'
100'
35' |
100'
100'
100'
23' |
100'
100'
---
--- |
110 85
67 10 --- |
**HS1
**HSUL-1 |
4"
6"
|
150,000
200,000
250,000
300,000
150,000
200,000
250,000
300,000
|
100'
87'
40'
4'
100'
100'
100'
30'
|
60'
57'
12'
---
100'
100'
92'
---
|
35'
27'
---
---
100'
100'
---
---
|
158 115 95
12 --- |
**HS2
**HSUL-2
|
6"
8"
|
350,000
400,000
450,000
500,000
550,000
600,000
350,000
400,000
450,000
500,000
550,000
600,000
|
100'
100'
100'
100'
94'
15'
100'
100'
100'
100'
100'
67'
|
100'
100'
100'
72'
---
---
100'
100'
100'
100'
---
---
|
100'
100'
67'
---
---
---
100'
100'
100'
---
---
---
|
286 235 215
196 158 |
** Oil applications must use HSJ, HS1 or
HS2 models including UC1 Universal Control with integral Pre and Post-Purge
settings. HSUL-Series only suitable for gas applications because no post-purge
is available.
HS-SERIES Power Venter
Dimensions
UNIT DIMENSIONS
MODEL
|
(H) HEIGHT
|
(W) WIDTH
|
(D) DEPTH
|
INLET/OUTLET
|
|
HSJ
HSUL-J |
7 7/8"
|
10 1/4"
|
7" |
4" |
HS1
HSUL-1 |
7 7/8"
|
11"
|
7" |
4" |
HS2
HSUL-2 |
9 1/4"
|
11 1/2"
|
8 1/2"
|
6" |
|
Ballpark
Pricing |
Pricing is based on
fan sizing with any accessories needed for the primary appliance and/or
any additional appliance.
A single residential appliance needing an HSJ/HS1 w/hood ranges
$375-$450. Add $125-$200 in controls to add an additional
appliance.
Provide BTU input for appliance(s) for a proper quote.
Usually ships UPS Ground.
No tax out of NY. |
HS3, 4, 5 COMMERCIAL SERIES
POWER VENTERS |
Side Wall or Vertically Vent
Commercial Boilers and Water Heaters with Capacities up to 1,825,000
BTU/hr. |
Now includes UC1 Universal
Control for easier installation, increased safety, performance and
control . |
Vent any
atmospheric or power burner. |
Reduced cost compared to
manufactured chimneys. |
Safely down-size vent pipe by
up to 50%. |
Reliable and consistent
Mechanical Draft. |
Factory calibrated Fan Proving
Switch. |
Simple, straight forward
installation. |
Easily add
multiple heaters with one Venter with MAC-Series Multiple Appliance
controls. |
HS Series Commercial
Models: HS3, HS4, HS5
Used for Side wall venting
commercial natural gas or LP fired equipment including: boilers, water heaters
and unit heaters. All models feature the new UC1 Universal Control and a
diaphragm Fan Proving Switch safety interlock which will shut down heating
equipment if a venting malfunction occurs. UC1 Universal Control features
include; adjustable pre and post-purge settings, LED Status/diagnostic
indicators, Fan Prover switch monitoring. Interlocks with any 24-120 VAC burner
control circuit and also includes "dry" contact actuation option. Easily
interlock multiple appliances with our MAC-Series multiple appliance controls.
Allows for a significant reduction in vent
pipe diameter to save on costly materials and labor.
Built-in adjustable damper also allows regulation for maximum combustion
efficiency.
MODEL SELECTION TABLE
MODEL
NUMBERS |
VENT
PIPE
DIA. |
BTU/HR
INPUT |
MAXIMUM PIPE LENGTH
(FEET)
AT STACK TEMP
100% DILUTION 300 F
GAS FIRED ATMOSPHERIC WITH
DRAFT HOOD OR DRAFT DIVERTER
|
MAXIMUM PIPE LENGTH
(FEET)
AT STACK TEMP
25% DILUTION 400 F
GAS FIRED POWER BURNER WITH
BAROMETRIC DRAFT CONTROL
|
HS3
115 VAC
1/4 HP
2.7 AMPS
|
8"
10"
|
450,000
500,000
600,000
700,000
450,000
500,000
600,000
700,000
|
100'
100'
100'
7'
100'
100'
100'
21'
|
100'
100'
100'
100'
100'
100'
100'
100'
|
HS4
115 VAC
1/3 HP
5.8 AMPS
|
8"
10"
12"
|
700,000
800,000
900,000
1,000,000
1,100,000
1,200,000
700,000
800,000
900,000
1,000,000
1,100,000
1,200,000
700,000
800,000
900,000
1,000,000
1,100,000
1,200,000
|
100'
100'
100'
70'
32'
5'
100'
100'
100'
100'
97'
14'
100'
100'
100'
100'
100'
34'
|
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
|
HS5
115/208/230 VAC
1 HP
6.2 AMPS @ 208V*
6.3 AMPS @ 230V *
12.6 AMPS @ 115V
|
10"
12"
14"
|
1,200,000
1,400,000
1,600,000
1,825,000
1,200,000
1,400,000
1,600,000
1,825,000
1,200,000
1,400,000
1,600,000
1,825,000
|
100'
100'
100'
29'
100'
100'
100'
72'
100'
100'
100'
100'
|
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
100'
|
Table is based on straight vent pipe. 90
degree elbows are equivalent to 10 feet of straight vent pipe, 45 degree elbows
are equivalent to 5 feet of straight vent pipe.
Tjernlund Commercial Power Vent Systems
include all necessary actuation, operation and safety controls.
*A SPDT motor relay must be added for use
with the UC1 Universal Control.
POWER VENTER
DIMENSIONS
MODEL
|
A
|
B
|
C |
|
HS3
|
8" |
12 1/2"
|
13 1/4"
|
HS4
|
8' |
14 3/4"
|
15 1/4"
|
HS5
|
10"
|
18"
|
16 1/2"
|
VH1-Series
Models: VH1-3,
VH1-4, VH1-6, VH1-8, VH1-10Specially designed
to terminate Tjernlund Side Wall Vent Systems. They are also an
approved method of terminating many horizontally vented appliances. Vent hoods
feature heavy duty, corrosion resistant aluminum construction. Models VH1-3, 4
and 6 also have an additional heat shield for built in clearances from
combustibles. Building exteriors are kept clean while the aesthetics of the
structure remain undisturbed. All mounting hardware is included.
DIMENSIONS
MODEL
|
A Dia.
|
B |
C |
D |
E |
F |
G |
ROUGH-IN
DIMENSIONS |
|
VH1-3
|
3" |
6 1/4" SQ
|
8 1/2"
|
10"
|
10"
|
5 1/4"
|
7 3/4"
|
6 3/4" SQ
|
VH1-4
|
4" |
7 1/2" SQ
|
7 1/8"
|
13"
|
8 5/8"
|
7 3/8"
|
11"
|
8" SQ
|
VH1-6
|
6" |
8 1/2" Dia.
|
7 7/8"
|
12"
|
9 1/2"
|
10 1/2"
|
10"
|
9" Dia.
|
DIMENSIONS
MODEL
|
A Dia.
|
B |
C |
D |
E |
ROUGH-IN
DIMENSIONS |
|
VH1-8
|
8" |
16"
|
7 3/4"
|
18 3/8"
|
20"
|
8 1/2" Dia.
|
VH1-10
|
10"
|
16"
|
7 3/4"
|
18 3/8"
|
20"
|
10 1/2" Dia.
|
VP-2F MILLIVOLT WATER HEATER VENTING PACKAGE
FOR $374.99 delivered*
Side power venter for a single residential gas appliance.
Unsure? Provide BTU input for appliance and zip code for a quote..
Usually ships UPS Ground. No tax out of NY. |
|
Click to learn more
e |
Click here for Prices, Quotes & E-mail att
info@volko.com
|